Browse all practice questions for the Colorado Journeyman Practice Exam. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Ace the Colorado Journeyman Challenge 2026 – Empower Your Skills and Build Your Future! course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • What is the definition of electronic computer processing equipment?
  • What is the maximum number of No. 14 AWG THHN copper conductors allowed in 3/8-inch flexible metal conduit using external clamp-type fittings?
  • What is a legal requirement for repairing an electrical code violation in Colorado?
  • In one- or two-family dwellings, what is the maximum length for the primary protector bonding conductor or grounding electrode conductor?
  • A ground rod must be a minimum of how many feet in length?
  • What is one key factor when determining the ampacity of a motor circuit?
  • What is the maximum secondary circuit voltage for sign transformers?
  • What is a common application for OFCP cable?
  • What is the primary material used for electrical service conductors in Colorado?
  • What term is used for mandatory rules in the NEC characterized by the use of the word "shall"?
  • What is the function of a ground fault circuit interrupter (GFCI)?
  • What percentage of campsites in a new recreational vehicle park must have a 50-ampere 120/240-volt supply installed?
  • What type of wiring is commonly used in residential electrical systems in Colorado?
  • Which circuit component is crucial for protecting against voltage spikes?
  • What is the preferred method for grounding a service in Colorado?
  • What do you call the electrical system grounding point created by a common ground?
  • What is a branch circuit with two or more un-grounded conductors called when it has equal voltage to a grounded conductor?
  • Which of the following is not required to be bonded on a hot tub installation?
  • What is the primary purpose of using conduit in electrical installations?
  • What is the allowable ampacity for a 30 AWG conductor used as part of the control wiring in a permanent amusement attraction?
  • Which of the following equipment does Article 430 primarily apply to?
  • Which part of the Colorado Administrative Code contains the laws regulating electrical installation?
  • How often must electrical installations in commercial buildings be inspected?
  • What is the purpose of the Colorado Electrical Board?
  • Under what circumstance can an electrical panel be mounted higher than 6.5 feet above the ground?
  • For a single-phase motor fed from an underground source, where should the motor overload unit be placed?
  • What Code requirement applies to a wall receptacle installed within 6 feet of a wet bar in a family room?
  • A "park trailer" is defined as having a gross trailer area not exceeding __________ sq. ft. in set up mode.
  • A multiwire branch circuit must have a means to disconnect all un-grounded conductors in what manner?
  • What is the minimum height above finished grade for receptacles located outside?
  • In a 120/240-volt, single-phase, 200-ampere service, what is required for the main bonding jumper connection to the service equipment enclosure?
  • What determines the lifting load limit for existing structures when installing new electrical services?
  • Which of the following is typically required for outdoor wiring installations?
  • Which of the following describes the Code requirements for a 125-volt, 20-ampere outdoor receptacle in a bathroom?
  • In regards to flexible cords, which situation is permissible?
  • What is the purpose of using multi-wire branch circuits?
  • Which of the following built-in appliances can be connected using a cord and plug in a dwelling?
  • How many outdoor receptacles are required at a dwelling unit?
  • What kind of protection is required between conductors and armor in armored cable?
  • Sills or curbs in transformer vaults, shall have a minimum height of __________.
  • What designation is used for overhead power lines that are less than 600 volts?
  • What type of receptacle is required in outdoor locations according to the electrical code?
  • What is the minimum voltage for low voltage lighting systems?
  • Which type of circuit breaker is used to protect the primary side of a transformer with a secondary connected to industrial equipment?
  • What is the minimum height for outdoor service conductors to ensure safety?
  • The total square inch area of a three-inch intermediate metal conduit is __________.
  • What is the allowable voltage drop for branch circuits according to the NEC?
  • What feature must dry-type transformers have when installed outdoors?
  • To what maximum percentage can splices and taps fill a surface nonmetallic raceway?
  • What is the minimum size copper wire allowed for residential branch circuits in Colorado?
  • What type of circuit wiring cannot be run through raceways according to the NEC?
  • What does the term "ampacity" refer to?
  • Which section of the NEC covers the general requirements for electrical installations?
  • What is a common installation practice for mounting electrical panels?
  • What determines the number of branch circuits required for a residential structure?
  • What is the maximum permitted cord- and plug-connected load to a 15-ampere receptacle?
  • The definition of a forming shell as used in a swimming pool is best described as which of the following?
  • What is called the "electric power production and distribution network"?
  • What device is used to prevent overcurrent in electrical circuits?
  • What is the definition of a "lighting outlet" in NEC terms?
  • In Colorado, what is the estimated penalty for performing electrical work without a license?
  • Which term defines "a unit of an electrical system that carries or controls electric energy as its principal function"?
  • What is the minimum size aluminum equipment-grounding conductor required for a feeder of four three-phase motors?
  • Remote-control circuits to safety-control equipment classified as Class __________ involve a direct fire or life hazard.
  • If a raceway is installed in a wet location above grade, how is its interior classified?
  • What is the minimum size of the service entrance conductors for a dwelling unit with five 2-wire branch circuits?
  • Which cable type is permitted to be used as a substitute for BLX?
  • "Connected to the ground or to a conductive body that extends the ground connection." refers to which term?
  • When calculating demand loads for a dwelling unit, which types of loads must be considered?
  • Which of the following cannot be used as a grounding electrode?
  • What is the required insulation temperature rating for branch-circuit conductors near a ballast?
  • For residential electrical systems, what is the required minimum number of circuits in the kitchen?
  • What is the voltage drop for a three-phase, 3-wire, 240-volt circuit with a load of 5 HP located 110 ft away from the panel using No. 8 AWG copper THHN?
  • What are feeder conductors used for?
  • Which of the following components provides a protective measure by interrupting the flow of electricity in case of a ground fault?
  • What is the recommended accepted standard for branch circuit protection of electric motors?
  • A device that connects bonding conductors for communication systems to the grounding electrode system is known as _____________.
  • What is the primary purpose of a circuit breaker?
  • What is the maximum number of outlets allowed on a 15-amp circuit in a residential setting?
  • In a 1,600 sq. ft. dwelling unit with 74 receptacle outlets, what is the calculated feeder load for lighting and other loads?
  • According to NEC code, how many receptacles are allowed in a kitchen area for small appliances?
  • What type of receptacles must be installed in areas where electrical diagnostic equipment or portable lighting is used?
  • What must be provided between conductors and armor in armored cable installation?
  • What is the minimum size required for secondary conductors if a transformer has no secondary conductor protection?
  • What is the primary purpose of AFCI protection in residential circuits?
  • What percentage of ampacity must be applied to conductors when housed together in a raceway?
  • What is the minimum ampacity required for branch-circuit conductors for a 115-volt, 3 HP motor with a nameplate current rating of 36.5 amperes?
  • What is the acceptable temperature range for residential wiring in Colorado?
  • Which article of the NEC pertains to hazardous locations?
  • What is the minimum ampacity required to supply a 12.0 kW electric furnace with a 1/3-HP motor at 240 volts?
  • What is a feeder in electrical systems?
  • According to code, how many telephone outlets are required for new dwellings?
  • Which color indicates a ground wire in residential wiring?
  • What is the term used for notes that provide additional information but are not mandatory?
  • Transformers and transformer vaults shall be __________ to qualified personnel for inspection and maintenance.
  • The overcurrent protection device on the primary side of a transformer operating at less than 1000 volts must be set at no more than __________ percent of the transformer’s rated primary current?
  • How close to the nearest edge can NMC be installed when parallel to framing members?
  • Which section of the NEC deals with swimming pool installations?
  • What is the minimum ampacity permitted for the feeder supplying a group of single-phase squirrel-cage induction motors totaling 32.5 HP?
  • The listed exposed work cover is permitted to serve as the grounding and bonding means when mounted correctly. What is required for this?
  • What is the code section that specifies requirements for working safely near overhead power lines?
  • What must replace a two-wire receptacle in a bathroom when no grounding conductor is available?
  • A listed package spa assembly with a factory-installed ground-fault circuit-interrupter is connected indoors to a wall receptacle. What is required for compliance?
  • What is the primary function of a device in an electrical system?
  • In regards to freestanding receptacles, which of the following is true?
  • How long must electrical records be retained according to Colorado regulations?
  • A __________ shall be installed where cables emerge from raceway used for mechanical support or protection in accordance with code guidelines.
  • A mobile home park with 26 mobile homes having a computed load of 22,000 volt-amperes requires service conductors with what ampacity?
  • How is "voltage" defined?
  • What tool is commonly used to measure electrical current?
  • What is the minimum age requirement to take the Colorado Journeyman Exam?
  • What safety test must GFCI outlets pass before installation?
  • How far must an outlet for laundry equipment be installed from the intended location of the appliance?
  • In an electrical circuit, what does GFCI stand for?
  • How many grounding electrodes are required for a residential service system?
  • What is the maximum number of 15- and 20-ampere receptacles permitted in a single circuit?
  • Which of the following best describes the purpose of an electrical transformer?
  • What is the largest circuit breaker allowed to protect a 25 HP three-phase, 480-volt induction motor?
  • What is required for all electrical installations in terms of accessibility?
  • How much change in length would 100 ft of PVC conduit experience with temperature fluctuations from -10°F to 110°F?
  • What adjustment factor is applied to 4 pieces of 12/2 MC cable supplying 240-volt single-phase loads?
  • Which type of cable is permitted to be used as a substitute for OFCR?
  • What type of conduit should a feeder from a dwelling unit to a detached garage be installed in?
  • The conductive path installed to connect normally non-current carrying metal parts of equipment to the grounded conductor is called the ___________?
  • Which of the following is not a purpose of electrical codes?
  • Code requirements state that the disconnecting means for a circuit providing power to a pump for an LP-Gas filling station must include which of the following?
  • What is the operating maximum voltage for a typical residential electrical system in Colorado?
  • What does the acronym "NEC" stand for?
  • What is the primary insulation rating required for conductors in damp locations?
  • What is the primary purpose of grounding in electrical systems?
  • Each kitchen is required to have a minimum of how many small appliance branch circuits?
  • What is the proper method for splicing two conductors together?
  • What is the minimum height for a service drop above a residential driveway?
  • When passing over roofs, coaxial cables shall have at least __________ ft of clearance from all points on the roof.
  • What is a major benefit of having service entrance cables rated for wet locations?
  • What should be considered when choosing fuses for motor circuits?
  • What is the maximum riser length allowed for a service drop in residential installations?
  • What is the minimum distance for nonmetallic-sheathed cable from the edge of a scuttle hole in an attic?
  • For motors rated at over 10 HP, which standard must be referred to for necessary protection?
  • Are sign transformers covered by Article 450?
  • Which of the following uses is not acceptable for flexible cords?
  • How are circuit conductors identified according to the NEC?
  • Which type of circuit breaker is designed to protect against ground faults?
  • What is the maximum interval at which Liquidtight Flexible Metal Conduit must be supported?
  • "The greatest root-mean-square difference of potential between any two conductors of the circuit concerned" is known as what?
  • What is a common method to calculate load for a dwelling unit?
  • For a 10kVA single-phase transformer with a 30 amp circuit breaker on the primary, what is the minimum size allowed for secondary conductors?
  • Which of the following is a common cause of electrical fires?
  • In Colorado, what is the code enforcement body for electrical work?
  • How often is the National Electrical Code updated?
  • What device is required to protect circuits that are installed in locations prone to moisture?
  • What constitutes a violation when installing receptacles in a residential dwelling?
  • What type of fault is mainly prevented by the use of GFCI devices?
  • What is the allowable ampacity reduction percentage for raceways with 10 current-carrying conductors according to standard guidelines?
  • How many No. 4/0 THW copper conductors may be installed in a 2-1/2-inch EMT conduit nipple six inches long installed between a panel and a wireway?
  • Each patient location in a health care facility shall be supplied by at least __________ branch circuits.
  • What type of insulation is required for conductors located in a damp environment?
  • What is the primary code book used for the Colorado Journeyman Exam?
  • What does the color black typically represent in residential electrical wiring?
  • According to electrical codes, how far from a scuttle hole should nonmetallic cable be placed unless protected by guard strips?
  • What type of circuit protects against short circuits and overloads?
  • What is the purpose of a service lateral?
  • What is a significant benefit of using AFCI breakers in residential settings?
  • What is the minimum size THWN aluminum service conductor permitted by Code to supply a 400-ampere, 120/240-volt service to a single family dwelling?
  • What is the function of a disconnect switch in an electrical system?
  • Which of the following is not an approved fixed wiring method for a place of assembly?
  • What is the minimum wire size for a bonding bar connected to the equipment grounding conductors in the service equipment enclosure?
  • Which Code article specifies the minimum requirements for service conductors feeding a 400-ampere service?
  • What is the primary function of a junction box in electrical systems?
  • For a grounded 400-ampere AC system, what is the minimum wire size permitted for the grounding-electrode conductor connected to a rod or pipe electrode?
  • What is the minimum number of receptacles required for a 6-foot wide kitchen counter top?
  • What is the feeder demand load for four 14kW residential ranges?
  • Which section of the NEC addresses outdoor and special-purpose installations?
  • What is the common term for a circuit that uses both 120V and 240V?
  • Which component is essential for providing safety in wet locations when referring to electrical installations?
  • Which code revision year is commonly used as a reference for current electrical installations?
  • What is the term for the conductive paths that provide a ground-fault current path in electrical equipment?
  • What is the primary function of a GFCI protected receptacle?
  • Given a transformer with a primary rating of 1000 volts and rated primary amperage of 5 amps, the overcurrent protection device rating shall not exceed __________?
  • What is the maximum time-delay fuse permitted for a No. 1 AWG copper THHN motor feeder for five 480-volt, 3-phase induction motors?
  • Class 2 and Class 3 remote control and signaling circuit wiring shall not be secured to what?
  • What is the minimum height for installing a residential service entrance?
Subscribe

Get the latest from Examzify

You can unsubscribe at any time. Read our privacy policy